FRIESS 1U compact oil skimmer

Small tanks. Continuous oil recovery.

FRIESS 1U
Compact Oil Skimmer

Continuous floating-oil recovery for small tanks with limited mounting space. The FRIESS 1U uses an oleophilic collection tube for machine-tool sumps, emulsion tanks, washing tanks and degreasing baths.

2–30 L/h oil recovery · 0.09 kW drive

Mounting height up to 600 mm above the liquid. Confirm the configuration against tank dimensions, liquid-level changes and the oil-discharge arrangement.

1 L Oil Recovery Demonstration

See how the 1U collects floating oil after 1 L of oil is added to a demonstration tank, then scrapes it from the tube into a collection container. The video shows the operating process; actual recovery depends on the oil and site conditions.

Why Choose the 1U?

01

Adjustable Installation Angle

Adjust the mounting angle to suit the height above the liquid and the installation position.

02

Continuous Oil Recovery

Continuously collects free oil from the surface, helping reduce manual skimming and supporting routine fluid maintenance.

03

Accommodates Level Changes

The floating tube follows the liquid surface. Confirm minimum and maximum levels, plus clearance along the tube route.

04

Wear-Resistant Construction

Ceramic or hardened-steel wear parts help reduce wear. Regular inspection and cleaning remain necessary.

Installation Around Your Tank

Adjust the mounting angle to suit the height above the liquid and the installation position. Allow clearance for the collection tube, oil discharge and routine inspection. Check tank dimensions, minimum and maximum liquid levels, and mounting height above the liquid.

Continuous Oil Collection and Discharge

Watch the collection tube contact the liquid surface, carry floating oil back to the skimmer and discharge it continuously. Allow space for tube movement, oil discharge and routine inspection.

1U Product & Installation Photos

1U Technical Specifications

Drive power

0.09 kW

Oil recovery

2–30 L/h

Operating temperature

≤ 60 °C

Dimensions incl. tray

228 × 224 × max. 270 mm (W × L × H)

Minimum tank surface

400 × 400 mm

Mounting height above liquid

≤ 600 mm

Total collection-tube length

≤ 3,000 mm

Weight

9 kg

The 600 mm limit is the mounting height above the liquid, not the permitted liquid-level variation. The standard 3 m tube limit refers to total length. Confirm coverage against liquid levels and the tube route; custom extended configurations require separate assessment.

Applications & Selection

For floating-oil recovery from machine-tool sumps, small emulsion tanks, washing tanks and degreasing baths.

We will assess 1U suitability and recommend the installation angle, collection-tube configuration and oil-discharge arrangement. Share the information you have; you do not need to choose the configuration first.

Oil Skimming Case Studies

1U Selection FAQs

The minimum tank surface is 400 × 400 mm, with a mounting height up to 600 mm above the liquid. Typical applications include machine-tool sumps, small emulsion tanks and degreasing baths. Confirm tank shape, liquid-level changes, mounting space and the oil-discharge route before selecting a configuration.

Both models have a rated oil recovery range of 2–30 L/h. The main difference is mounting height above the liquid: up to 600 mm for the 1U and up to 10 m for the 1S. Assess the 1U for mounting beside a tank; consider the 1S for pump pits, underground tanks or elevated installation positions.

The standard 3 m limit refers to total collection-tube length, not the length of tank it can cover. Part of the tube connects the liquid surface to the skimmer. Actual coverage depends on mounting height, tank shape, tube guidance and liquid-level changes. Custom extended configurations require separate assessment.

The rated recovery range is 2–30 L/h. Actual recovery depends on oil viscosity, temperature, layer thickness and surface movement. Share the process fluid, oil type and expected floating-oil load so the configuration can be assessed.

The 1U is suitable for continuous operation. Inspect the collection tube, guides and scraper parts regularly, remove deposits, and check the discharge route and collection container. Set inspection intervals according to the amount of particles, sludge and other contamination.

The 1U recovers floating free oil and tramp oil from the liquid surface. It does not separate stable emulsified oil. Confirm whether the contaminating oil separates from the process fluid, then assess suitability against the fluid and treatment objective.

Floating oil keeps building up in a small tank?

Share these details to assess a suitable 1U configuration:

  • Tank length, width and depth, plus minimum and maximum liquid levels
  • Proposed mounting position, height above the liquid and available space
  • Process fluid, floating-oil type, temperature and expected recovery requirement
  • Oil-discharge route, collection-container arrangement and site photos

Tell Us What You Need — Our Engineer Will Recommend a Solution

Where will the equipment be installed? If the location is not yet confirmed, please say so.
By submitting this form, you agree that Wuhan Ouyi may use the information provided to respond to your enquiry in accordance with our Privacy Policy. Please do not include sensitive personal information.